Powerex Medical Packing System MPQ User Manual Page 5

  • Download
  • Add to my manuals
  • Print
  • Page
    / 27
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 4
Tank Drain moisture Daily 2500
Inlet air filter Replace ●▲(Every 2,500 hrs or less)
Blower fan Clean ●●●●
Fan Duct Clean ●●●●
Compressor Fins Clean (Every 2,500 hrs or less)
Bearings Replace ●●▲
Compression rings Replace ▲▲
Wrist pin bearing Regrease ▲▲
Piston set Replace
V-belt Inspect, replace *Note 3 ▲▲▲▲
Safety valve Confirm operation (Every 2,500 hrs or less)
Pressure gauge Inspect (Every 2,500 hrs or less)
Air leaks Inspect ●●●
Filters Replace ▲▲▲▲▲ (View delta pressure
indication)
Moisture drains Inspect ●●●
traps
Suction pressure ●●●●●
(refrigerated)
Heat exchanger ●●●●●
Medical Package System
COMPRESSOR MAINTENANCE SCHEDULE
Operating Hours
Item Action needed 500 2500 5000 10,000 15,000 20,000 Remarks
QUADPLEX MPQ
TRIPLEX MPT
DUPLEX MPD DRYER SYSTEM
MDR OR MDD
FILTER SYSTEM
MFP
LEFT
END
VIEW
RIGHT
END
VIEW
Consult factory
for special voltages
or arrangements.
32" 32" 8"32"
5
1. Inspect and perform maintenance periodically according to maintenance schedule.
2. The maintenance schedule relates to the normal operating conditions. If the circumstances and load condition are adverse, shorten the cycle time and do
maintenance accordingly.
3. * The tension of the V-belt should be adjusted during the initial stage and inspected every 1,500 hours afterwards. Proper belt tension for 3/4 to 3 HP units is
12 lbs./.5 deflection; for 5 to 20 HP units, 16 lbs./1.5 deflection
Inspect Replace
++
facing the black fan shroud and
counterclockwise if facing the
compressor flywheel.)
c. Set both selector switches to the
auto position. Compressors will
both run until the lead pressure
switch closes.
d.Open valve at the air receiver
leading to Medical Air System.
e. Check for air leaks at the
connections.
9. Check that the compressor operates
without excessive vibration, unusual
noises or leaks.
10. Check the discharge pressure. Also
make sure the air pressure rises to the
designated pressure setting by
checking the discharge pressure
gauge.
11.Check the operation of the pressure
switch or the pilot valve for
continuous run units by opening
the stop valve and confirming the
compressor starts or reloads as
pressure drops.